APC Smart-UPS X 3000VA Rack/Tower LCD
Part# SMX3000RMHV2U
EAN:0731304268529
APC Smart-UPS X 3000 Rack/Tower LCD - UPS - AC 208/230 V - 2.7 kW - 3000 VA - 1-phase - RS-232, USB - output connectors: 11 - 2U - black - APC Take-Back
Native product specifications. The product description originates from 1WorldSync. Foxway accepts no responsibility for error or misinformation in product descriptions from 1WorldSync.
Product specifications
| Product Description | APC Smart-UPS X 3000 Rack/Tower LCD - UPS - 2.7 kW - 3000 VA |
| Manufacturer Warranty | 3-year warranty |
| Dimensions (WxDxH) | 43.2 cm x 66.7 cm x 8.5 cm |
| Weight | 37.3 kg |
| Networking | RS-232, USB |
| Device Type | UPS - external |
| Battery | Lead Acid |
| Input Voltage | AC 208/230 V |
| Output Voltage | AC 208/230 V ± 5% |
| Colour | Black |
| Rack Size | 2U |
| Run Time (Up To) | 6.3 min at full load |
| Input Wiring | 1-phase |
| Pricing Type | APC Take-Back |
| Power Capacity | 2.7 kW / 3000 VA |
| Designed For | P/N: AR2487G, AR3100W, AR3105SP, AR3105W, AR3140G, AR3140W, AR3150W, AR3155W, AR3305W, AR3340G, AR3355SP, AR3355W, AR4018IX429, AR4018SP, AR4018SPX429, AR4018SPX431, AR4018SPX432, AR4018X429, AR4024IX431, AR4024SP, AR4024SPX429, AR4024SPX431, AR4024SPX432, AR4038IX432, NBWL0356A, SRT1000RMXLA |
| Input Connectors | Power IEC 60320 C20, power CEE 7/7, power BS 1363A |
| Output connectors | 8 x power IEC 60320 C13 ¦ 2 x IEC jumper ¦ 1 x power IEC 60320 C19 |
General features
| Device Type | UPS - external |
| Height (Rack Units) | 2U |
| Colour | Black |
Porte
| Interfaces | 1 x EPO (emergency power off) |
| Expansion Slots | 1 (total) / 1 (free) x SmartSlot |
Warranty
| Service & Support | Limited warranty - 3 years ¦ Limited warranty - battery - 2 years |
Network
| Remote Management Interface | RS-232, USB |
Compliance
| Cables Included | Serial cable ¦ USB cable ¦ Power cable 1.8 m |
| Rack Mounting Kit | Included |
| Features | Audible alarm, emergency power off, LCD display, LED indicators |
| Compliant Standards | CSA, C-Tick, GOST, EN 60950, UL 1449, UL 1778, VDE, EN 50091-2, RoHS Exemption 7b, IRAM, EN 50091-1, FCC Part 15 A, REACH |
| Pricing Type | APC Take-Back |
Software
| Software Included | APC PowerChute Business Edition |
HDD / SSD tolerance
| Min Operating Temperature | 0 °C |
| Max Operating Temperature | 40 °C |
| Humidity Range Operating | 0 - 95% |
| Sound Emission | 55 dBA |
Battery
| Technology | Lead Acid |
| Run Time (Up To) | 6.3 min at full load ¦ 18 min at half load |
| Recharge Time | 3 hours |
Capacity
| UPS Technology | Line interactive |
| Input Voltage | AC 208/230 V |
| Input Voltage Range | AC 141 - 255 / 160 - 280 V |
| Frequency Provided | 47 - 63 Hz |
| Input Wiring | 1-phase |
| Frequency Required | 47 - 63 Hz |
| Input Connectors | Power IEC 60320 C20, power CEE 7/7, power BS 1363A |
| Power Output Connectors Details | 8 x power IEC 60320 C13 ¦ 2 x IEC jumper ¦ 1 x power IEC 60320 C19 |
| Output Voltage | AC 208/230 V ± 5% - 47 - 63 Hz |
| Power Capacity | 2.7 kW / 3000 VA |
| Output Waveform | Sinewave |
| Surge Suppression | Yes |
| Surge Energy Rating | 645 Joules |
| Circuit Protection | Circuit breaker |
Physical dimensions
| Width | 43.2 cm |
| Depth | 66.7 cm |
| Height | 8.5 cm |
| Weight | 37.3 kg |
Shipping dimensions
| Shipping Width | 59.6 cm |
| Shipping Depth | 86.9 cm |
| Shipping Height | 24.3 cm |
| Shipping Weight | 45.4 kg |
Compatible with
| Designed For | P/N: ACCS1000, ACCS1001, ACCS1002, ACCS1003, ACCS1004, ACCS1005, ACCS1006, ACCS1007, ACDC1015, ACDC1016, ACDC1017, ACDC1019, ACDC1020, ACDC1021, ACDC2513, ACF001, ACF002, ACF003, ACF101BLK, ACF102BLK, ACF201BLK, ACF400, AP5017, AP5602, AP5606, AP5607, AP5616, AP92200, AP9290, AR202, AR203A, AR204A, AR2101, AR2102BLK, AR2144BLK, AR2145BLK, AR2200, AR2280, AR2400, AR2400FP1, AR2401, AR2407, AR2480, AR2487, AR2487G, AR2500, AR2507, AR2580, AR2587, AR2900, AR2901, AR3000, AR3100, AR3100G, AR3100SP, AR3100SP1, AR3100SP2, AR3100TAA, AR3100W, AR3100X609, AR3100X610, AR3100X617, AR3101, AR3104, AR3104SP1, AR3105, AR3105SP, AR3105W, AR3107, AR3107G, AR3107SP, AR3107X609, AR3107X610, AR3107X617, AR3130, AR3140, AR3140G, AR3140W, AR3150, AR3150SP, AR3150SP1, AR3150SP2, AR3150W, AR3150X609, AR3150X610, AR3150X617, AR3155, AR3155SP, AR3155W, AR3157, AR3157SP, AR3157X609, AR3157X610, AR3157X617, AR3200, AR3300, AR3300G, AR3300SP, AR3300W, AR3300X609, AR3300X610, AR3300X617, AR3305, AR3305SP, AR3305W, AR3307, AR3307SP, AR3307W, AR3307X609, AR3307X610, AR3307X617, AR3340, AR3340G, AR3340W, AR3347, AR3350, AR3350SP, AR3350W, AR3350X609, AR3350X610, AR3350X617, AR3355, AR3355SP, AR3355W, AR3357, AR3357SP, AR3357X609, AR3357X610, AR3357X617, AR3810, AR3812, AR3814, AR4018, AR4018A, AR4018I, AR4018IA, AR4018IX429, AR4018IX431, AR4018IX432, AR4018SP, AR4018SPX429, AR4018SPX431, AR4018SPX432, AR4018X429, AR4018X431, AR4018X432, AR4024, AR4024A, AR4024I, AR4024IA, AR4024IX429, AR4024IX431, AR4024IX432, AR4024SP, AR4024SPX429, AR4024SPX431, AR4024SPX432, AR4024X429, AR4024X431, AR4024X432, AR4038, AR4038A, AR4038I, AR4038IA, AR4038IX429, AR4038IX431, AR4038IX432, AR4038X429, AR4038X431, AR4038X432, AR7007, AR7050, AR7057, AR8135BLK, NBWL0356A, SMX2000LVNC, SRT1000RMXLA |
Specifications
Intelligent and efficient network power protection from entry level to scalable runtime. Ideal UPS for servers, point-of-sale, routers, switches, hubs and other network devices.
- Intuitive LCD interface
It provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys. - High frequency design
It reduces or eliminates bulky transformers resulting in lighter units for ease of handling. - Auto recognition of external batteries
UPS recognizes when external battery packs are attached and automatically adjusts runtime. - Predictive replace battery date
It dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning. - Green mode
Patent-pending operating mode bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection. - Energy meter
It provides actual kilowatt hours of usage for energy conscious users. - Audible alarms
Audible alarms provide notification of changing flywheel conditions - Pure sine wave output on battery
It simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics. - Multiple switched outlet groups
Multiple outlet groups that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding. - Wide input voltage range
Wide input voltage range is designed for harsh electrical environments to save battery life. - Battery failure notification
It provides early-warning fault analysis on batteries enabling timely preventive maintenance - High online efficiency
It reduces utility costs, generates less heat. - LED indicators
LED indicators provide easy-to-read status of your utility power conditions, UPS and battery. - Overload protection
It safeguards unit from damage by automatically turning it off in the event of a short circuit or overload. - Cold-start capable
It provides temporary battery power when the utility power is out. - Hot-swappable batteries
It ensures clean, uninterrupted power to protected equipment while batteries are being replaced - Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced. - Automatic restart of loads after UPS shutdown
It automatically starts up the connected equipment upon the return of utility power. - Adjustable voltage-transfer points
It maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. - Adjustable voltage sensitivity
It provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. - User-replaceable batteries
It increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR). - Serial connectivity
It provides management of the UPS via a serial port. - Temperature-compensated battery charging
It prolongs battery life by regulating the charge voltage according to battery temperature. - Boost and trim Automatic Voltage Regulation (AVR)
It gives higher application availability by correcting low and high voltage conditions without using the battery. - Scalable runtime
It allows additional run time to be quickly added as needed. - Intelligent battery management
It maximizes battery performance, life, and reliability through intelligent, precision charging. - Safety-agency approved
It ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. - Rack/tower convertible
It protects the initial investment in the UPS when migrating from tower to rack-mount environment. - Power conditioning
It protects connected loads from surges, spikes, lightning, and other power disturbances. - Network manageable
It provides remote management of the UPS over the network. - Frequency and voltage regulation
It gives higher application availability by correcting poor frequency and voltage conditions without using the battery. - Predictive failure notification
It provides early-warning fault analysis ensuring proactive component replacement.